MIL-DTL-83352D
TABLE VII: Examination of Product
No.
Defects
Critical
Major
Minor
1
Canted nozzle at rear of signal omitted 1/
X
2
Nozzle of signal incorrectly installed 1/
X
3
Nozzle clogged with foreign matter 2/
X
4
Launcher missing
X
101
Signal dented 1/
X
102
Loose actuation knob, collet, or handle of launcher 1/
X
103
Firing pin interfering with collet 1/
X
104
Color of signal assembly not as specified 3/
X
105
Diameter of unpainted surface of signal not as
X
specified 1/
106
Primer of signal omitted or incorrectly located 1/
X
107
Signal falls from collet when launcher is held with
X
distal end pointed down
108
Bandoleer containing less then 7 signals
X
201
Instruction sheet missing
X
202
Knurling omitted from launcher or lanyard of
X
launcher missing 1/
203
Burrs on launcher 1/
X
204
Plastic bag torn
X
205
Launcher not tied to bandoleer
X
1/ Inspection for this defect shall be performed prior to kit assembly.
2/ Nozzle holes should be visually inspected by using a minimum 3-power magnifying glass.
3/ This inspection shall pertain to the color of the signal only, for example, to determine that the
signal is painted red when a red (display) signal is specified and not to determine the color