MIL-DTL-83352D
TABLE VIII: Classification of Defects
No.
Defects
Critical
Major
Minor
5
Launcher holds signal captive while rocket motor
X
burns; signal explodes, deflagrates, or burns within
15 feet of launcher; or rocket motor vents and
snuffs out propellant system
6
Components of signal separate or come apart within
X
15 feet of launcher
7
Color of candle display not in accordance with
X
color identification of signal
8
Apogee of signal deviates more than 45 degrees
X
form vertical
X
109 Maximum height of display less than 400 feet for
signal that has been subjected to low temperature
conditioning
110 Maximum height of display less than 600 feet or
X
more than 1,600 feet
111 Maximum height of display exceeds 1,600 feet
X
after signal has been subjected to high temperature
conditioning.
112 Launcher requires maintenance before launcher
X
fires minimum of 7 signals
113 Display fails to meet burn time and candlepower
X
requirements of 3.5.2.1 and 3.5.2.2.
114 Apogee of display deviates more than 30 degrees
X
but less than 45 degrees from vertical
115 Burn time of display less than 7 seconds for red
X
signal (not conditioned) 1/
X
116 Burn time of display less than 4 seconds for red
signal that has been subjected to humidity or high
and low temperature conditioning
206 Display hitting ground while candle is still burning
X
207 Candle ignites below 400 feet
X
1/ Non-ignition of the display shall be considered zero burn time