MIL-DTL-10057J
DRAWING NUMBER
9256467
NEXT HIGHER
Hand grenade simulator M116A1.
4.3.2.11
ASSEMBLY
CONFORMANCE
REQUIREMENT INSPECTION
CLASSIFICATION
EXAMINATION OR TEST
CRITERIA
PARAGRAPH
METHOD
Critical
Visual
3.2.11
1
Charge on exterior of assembly
100%
Visual
2
Any opening in assembly through which
3.2.11
100%
powder may leak
Visual
3.2.11
3
Safety clip missing not fully engaged or
100%
incorrectly located.
Visual & Manual
3.2.11
4
Safety fuze loose at junction with top
100%
disc (can be moved by light finger
pressure).
4.6
3.2.11
5
Premature function (time for initiation to
100%
detonation less than 5 seconds)
Major
Visual
3.2.11
101
Fuze tape or sealing tape missing,
VL-IV
peeling or incorrectly positioned.
Visual
3.2.11
Vent holes missing from fuze tape.
102
VL-IV
Visual
3.2.11
Disc or tube puncture, cut or torn.
103
VL-IV
104
Assembly dented, or deformed.
Visual
3.2.11
VL-IV
Sealant cover on disc missing,
105
excessive or inadequate.