MIL-DTL-10057J
DRAWING NUMBER
9256467
Hand grenade simulator M116A1
NEXT HIGHER
(continued).
4.3.2.11
ASSEMBLY
CONFORMANCE
REQUIREMENT INSPECTION
CLASSIFICATION
EXAMINATION OR TEST
CRITERIA
PARAGRAPH
METHOD
Major
Visual
3.2.11
100%
106
Label missing or incorrect color
Visual
3.2.11
VL-IV
107
Label missing, peeling, misleading or
unidentifiable
Visual
3.2.11
VL-IV
108
Igniter damaged (punctured, torn, and
dented)
Visual
3.2.11
VL-IV
109
Evidence of poor workmanship on safety
fuze or igniter
110
Any component loose
3.2.11
Visual
111
Ferrule missing from safety fuze prior to
VL-IV
3.2.11
Visual
assembly into igniter
VL-IV
112
Delay time (between five (5) to six (6)
3.5.1
VL-IV
4.5.3
sec)
3.5.2
VL-IV
4.5.3
113
Delay time (over twelve (12) seconds)
3.5.3
VL-IV
4.5.3
114
Sound level (less than minimum)
3.5
VL-IV
4.5.3
115
Pull cord failure (pull cord breaks or
separates)
3.2.11
VL-II
Visual
116
Dud (assembly does not function "dud")
3.2.11.1
VL-II
Visual
Minor
3.7
VL-II
Visual
Protective coating damaged (bare spots)
201
Tube wrinkled
202
Poor workmanship
203
NOTES: