MIL-DTL-10058J
DRAWING NUMBER
7549246
4.3.2.13
Assembly (continued).
NEXT HIGHER
ASSEMBLY
CONFORMANCE
REQUIREMENT
EXAMINATION OR TEST
INSPECTION
CLASSIFICATION
CRITERIA
PARAGRAPH
METHOD
Major
109
Delay time (safety fuze delay between five (5)
Note a
3.5
4.6.3
110
to six (6) seconds DWG 7549246)
Delay time (safety fuze delay over maximum
Note a
3.5
4.6.3
DWG 8549246)
111
4.5.3
Functioning (No audible whistle)
Note a
3.5
Note a
3.5
4.5.3
112
Functioning (sound level intensity less than
Note a
3.5
4.5.3
113
minimum)
114
Functioning (assembly does not function
Note a
3.5
4.5.3
`dud")
Minor
Functioning (Pull cord breaks or separates)
201
Note a
3.5
4.7.1.1
202
VL-II
3.2.12.1
Visual
203
Functioning (whistle duration incorrect)
VL-II
3.7
Visual
Tube Wrinkled
Poor workmanship
NOTES:
a. Sample size shall be selected in accordance with 4.5.3