MIL-F-81738 (AS)
3.2.1 Components, assemblies and materials. All components, assemblies and
materials of the flare or Mk 45 drogue tray shall meet the requirements of their
respective specifications and drawings.
3.2.1.1 Fuze. The fuze shall meet the requirements of the applicable specification.
3.2.1.2 Primer. The primer shall meet the requirements of the applicable
specification.
3.2.1.3 Detonator. The detonator shall meet the requirements of the applicable
specification.
3.2.2 Flare. The flare shall meet the requirements of this specification.
3.2.3 Mk 45 Drogue Tray. The Mk 45 drogue tray shall meet the requirements of
this specification.
3.3 Performance and product characteristics. The flare or Mk 45 drogue tray shall
meet the acceptance criteria for performance and product characteristics in the se-
quence indicated in Table III.
3.3.1 Performance.
3.3.1.1 Sealing. The flare shall withstand a vacuum of 6.0 ± 1.0 inches of mer-
cury (24 inches of mercury absolute pressure) for a minimum period of 60 seconds
without signs of the leakage.
*
3.3,1.2 Candle burning. The candle assembly of the flare or Mk 45 drogue tray
shall meet the following requirements:
Attain a minimum candlepower of 1,000,000 within 10 seconds after
a.
ignition.
b. Shall not fall below 1,000,000 candlepower for any period greater than
5 seconds, for a continuous time period of 180 seconds, after initially reaching
1,000,000 candlepower.
c.
Produce a minimum average candlepower of 1,650,000 for a continuous
time period of 180 seconds, after initially reaching 1,000,000 candlepower.
d. Burning time: 180 seconds minimum (defined as that time period
beginning when the candlepower first reaches 1,000,000 and terminating when the
candlepower decays to 1,000,000 at burnout.
3.3.1.3 Static functioning. The flare shall meet the following requirements:
Shall not eject contents less than 1.5 seconds after pulling lanyard.
a.
b.
Ejection of the candle shall not result in ignition.